Harrier 15/80

Download Adobe PDF Data Sheet (682KB) 
Harrier 15/80

MSE have always had an enviable reputation for their bench top centrifuges and the HARRIER range continues this tradition. In addition to the existing HARRIER 15/80, the HARRIER 18/80 REFRIGERATED is designed for routine laboratory use and has the additional facility of being able to centrifuge samples at sub–ambient temperatures. Both centrifuges represent excellent value for money in terms of performance, ease of use, safety and reliability.

  • Intelligent Microprocessor Control
  • Inverter Controlled Brushless Motor
  • Automatic Rotor Identification System
  • Set And Run In RCF Or RPM
  • Key Lock Facility
  • Instant RCF Reading
  • Last Run Memory
  • Green Led Display
  • Overspeed Protection System
  • Full Lid Interlock
  • Imbalance Detection System
  • Self Diagnostics
 
  • Status Indicator
  • Removable Stainless Steel Inner Bowl (Harrier 15/80)
  • Simple And Easy To Use
  • Easy To Service
  • Superior Lid Lock Mechanism
  • 9 Acceleration Rates
  • 9 Brake Rates
  • Wide Range Of Accessories
  • All Accessories Fully Autoclavable
  • Sealed Buckets With Porton Down Approval
  • Sealed 24 Place Microtube Rotor Available
  • Designed To Comply With Bs En 61010-2-020: 1995
  • Language Options Available
Automatic rotor identification system
The HARRIER range incorporates an automatic rotor identification system. This important feature ensures that the centrifuge recognises the rotor in use and prevents it from being used beyond its safe maximum speed. As the centrifuge identifies the rotor in use, it can also work out the ‘g’ force at any set speed. This means the centrifuge can convert rpm to ‘g’ and vice versa once in use.
Microprocessor controlled induction drive
The HARRIER range utilises an induction motor for maintenance free long life operation. This motor has no carbon brushes so not only is there no need for routine maintenance but there is no build-up of carbon dust inside the centrifuge. This makes it suitable for use in clean environments. Microprocessor control combined with the frequency driven motor ensures accurate operation for run to run reproducibility.
Refrigerated version available
The HARRIER 18/80 REFRIGERATED combines all the capabilities of the proven HARRIER 15/80 in a refrigerated format. The selectable temperature range is from −90C to +40C and uses CFC–free R134a refrigerant gas. This means that in refrigerant terms, the HARRIER 18/80 REFRIGERATED complies with all the regulations pertaining to the Montreal Protocol. A precool facility allows the bowl to be cooled to the required temperature prior to use.
High speed microtube rotor
The use of the induction motor provides another benefit in that higher rotational speeds can be achieved. This allows the HARRIER range to have a maximum speed in excess of 15,000 rpm with the 24 place microtube rotor. The addition of refrigeration in the HARRIER 18/80 REFRIGERATED unit allows the microtube rotor an increase in speed to 18,000 rpm giving a maximum ‘g’ force of 28,980 ‘g. See rotor table for details.
Wide range of accessories available
For routine bench top work, the 4 x 200ml swing out rotor and 200ml sealed buckets are available on the HARRIER 15/80. A recent addition on the HARRIER 18/80R is the 4 x 200ml windshielded rotor. This uses the same 200ml buckets as used on the HARRIER 15/80 but with an increased speed capability of 6,000 rpm giving a maximum g force of 6,466 g. These, combined with a wide range of adaptors, can accommodate most manufacturers’ tubes. As well as the swing out rotor, other angle rotors and specialist rotors are available. Please see tables for details.
Harrier 15/80 Accessories Harrier 15/80 4 x 200ml Rotor and Adaptor

Specifications

Specifications
Max. Speed Swing–Out Rotor 4,500 rpm
Max. RCF Swing–Out Rotor 3,637 x g
Max. Speed Angle Rotor 6,500 rpm
Max. RCF Angle Rotor 5,574 x g
Max. Speed Microtube Rotor 15,000 rpm
Max. RCF Microtube Rotor 20,125 x g
Max. Bottle Size 200ml
Max. Capacity 800ml
Speed Control Range 1–15,000 rpm
Speed Control Accuracy 1 rpm
Speed Display ±10 rpm
Time Set Range
0–59 mins 59 secs
0–99 hours 59 mins
Time Hold
Time Accuracy 0.1 secs
Dimensions
Height 355mm
Width 470mm
Depth 580mm
Weight 41kg

Adaptors

Adaptors for 200ml Sealed Buckets (43551–1215) with 4 x 200ml Swing–Out Rotor (43124–134) Max. Speed 4,500 rpm
Cat. No. Adaptor Colour Rotor Capacity Max. Dia. Min. Length Max. Length Max. g (4,500 rpm)
34159–3021 1 x 100ml Brown 4 x 100ml 39.5mm 75mm 118mm 3,637
34159–3017 1 x 50ml Yellow 4 x 50ml 29.0mm 72mm 118mm 3,637
34159–3040 7 x 15ml Green 28 x 15ml 17.0mm 74mm 118mm 3,637
34159–3036 4 x 10ml (Flat Bottom Tube) Grey 16 x 10ml 16.5mm 43mm 110mm 3,600
34159–3055 9 x 7ml Orange 36 x 7ml 13.0mm 58mm 118mm 3,622
34159–306A 12 x 5ml Blue 48 x 5ml 12.0mm 49mm 118mm 3,637
34159–308 7 x 15ml (Flat Bottom Tube) Black 28 x 15ml 17.0mm 74mm 118mm 3,577
34159–309 1 x 50ml Falcon Beige 4 x 50ml 29.0mm 74mm 120mm 3,637
34159–310 3 x 15ml Falcon Maroon 12 x 15ml 17.0mm 90mm 120mm 3,637
Cat. No. Rotor Capacity Max. Dia. Min. Length Max. Length Max. g (4,500 rpm)
200ml Bottle (43551–103A) Does not require adaptor 4 x 200ml 57.7mm 120mm 3,631
4 x 30ml Universal Bucket (43551–1255) for use with 4 x 200ml Rotor (43124–134) Max. Speed 4,500 rpm
Cat. No. Adaptor Max. Dia. Min. Length Max. Length Max. g (4,500 rpm)
43551–1255 4 x 30ml (1 oz) 28.0mm 70mm 94mm 3,305
Trunnion Carrier for use with 4 x 200ml Rotor (43124–134) Max. Speed 4,500 rpm
Cat. No. Trunnion Carrier Capacity Sealed Bucket Adaptor for 50ml Falcon Max. Diameter Max. Length Max. g (4,500 rpm)
34136–110 2 x 50ml 8 x 50ml 43156–603 34142–110 30mm 120mm 3,780
Microtitration Rotor (43121–117) Max. Speed 2,600 rpm
Radius RCF Radius RCF No. Plates
113mm 854 130mm 982 2 per Carrier (4 in total)
Angle Rotors
Rotor Capacity Bucket Adaptor Max. Speed Max. RCF
43117–608 6 x 50ml 43156–602 6,500 rpm 5,574g
43117–607 12 x 15ml 43156–601 6,500 rpm 5,290g
43117–609 4 x 50ml
(Sealed)
43156–603
(Sealed Bucket)
34142–110
50ml Falcon
6,500 rpm 4,812g
High Speed Angle Rotor. Optional Sealing Lid Available (43117–614)
Rotor Capacity Max. Speed Max. RCF
43117–612 24 x 2ml 15,000 rpm 20,125g

Ordering Information

Model Description
MSB080.CX1.1 Harrier 15/80 120V 50/60Hz
MSB080.CX1.5 Harrier 15/80 220–230V 50/60Hz

Popular Systems

Harrier 15/80 with 4 x 200ml Swing–Out Rotor
Cat. No. Description Quantity
MSB080.CX… Order centrifuge to suit local voltage (see above) 1
43124–134 Swing–Out Rotor, 4 x 200ml (x1) 1
43551–1215 Sealed Buckets, Polycarbonate, 200ml (x4) 1
Adaptors Choose the relevant adaptors from above to suit your tubes (sold in sets of 4) 1
 
Harrier 15/80 with 12 x 15ml Angle Rotor (unsealed)
Cat. No. Description Quantity
MSB080.CX… Order centrifuge to suit local voltage (see above) 1
43117–607 Angle Rotor, 12 x 15ml (x1) 1
43156–601 Buckets, Stainless Steel, 15ml (x4) 3
 
Harrier 15/80 with 6 x 50ml Angle Rotor (unsealed – not for use with Falcon tubes)
Cat. No. Description Quantity
MSB080.CX… Order centrifuge to suit local voltage (see above) 1
43117–608 Angle Rotor, 6 x 50ml (x1) 1
43156–602 Buckets, 50ml (x4) 2
 
Harrier 15/80 with 4 x 50ml Sealed Angle Rotor (can be used with Falcon tubes)
Cat. No. Description Quantity
MSB080.CX… Order centrifuge to suit local voltage (see above) 1
43117–609 Sealed Angle Rotor, 4 x 50ml 1
43156–603 Sealed Bucket, Aluminium, 50ml (x4) 1
34142–110 Adaptor, Conical, 50ml in 43156–603 (x12) 1
 
Harrier 15/80 with 8 x 50ml Swing–Out Rotor (can be used with Falcon tubes)
Cat. No. Description Quantity
MSB080.CX… Order centrifuge to suit local voltage (see above) 1
43124–134 Swing–Out Rotor, 4 x 200ml (x1) 1
34136–110 Trunnion, 2 x 50ml (x4) 1
43156–603 Sealed Bucket, Aluminium, 50ml (x4) 2
34142–110 Adaptor, Conical, 50ml in 43156–603 (x12) 1
 
Harrier 15/80 with 24 x 2ml Angle Rotor at 15,000 rpm
Cat. No. Description Quantity
MSB080.CX… Order centrifuge to suit local voltage (see above) 1
43117–612 Angle Rotor, 24 x 2ml, 15,000 rpm 1
Optional
43117–614 Lid for 43117–612 (x1) 1
 
Harrier 15/80 with Microtitration Rotor Plate
Cat. No. Description Quantity
MSB080.CX… Order centrifuge to suit local voltage (see above) 1
43121–117 Microtitre Rotor 1