Harrier 18/80R |
| MSE have always had an enviable reputation for their bench top centrifuges andthe HARRIER range continues this tradition. In addition to the existing HARRIER 15/80, the HARRIER 18/80 REFRIGERATED is designed for routine laboratory use and has the additional facility of being able to centrifuge samples at sub-ambient temperatures. Both centrifuges represent excellent valuefor money in terms of performance, ease of use, safety and reliability.
- Intelligent Microprocessor Control
- Inverter Controlled Brushless Motor
- Automatic Rotor Identification System
- Set And Run In RCF Or RPM
- Key Lock Facility
- Instant RCF Reading
- Last Run Memory
- Green Led Display
- Overspeed Protection System
- Full Lid Interlock
- Imbalance Detection System
- Self Diagnostics
- Status Indicator
- CFC - Free Refrigerant Gas (Harrier 18/80R)
|
|
- Fast Efficient Cooling (Harrier 18/80R)
- Precool Facility (Harrier 18/80R)
- CFC-Free Insulation (Harrier 18/80R)
- Simple And Easy To Use
- Easy To Service
- Superior Lid Lock Mechanism
- 9 Acceleration Rates
- 9 Brake Rates
- Wide Range Of Accessories
- All Accessories Fully Autoclavable
- Sealed Buckets With Porton Down Approval
- Sealed 24 Place Microtube Rotor Available
- Designed To Comply With Bs En 61010-2-020: 1995
- Language Options Available
- Selectable Temperature Range -9C To +40C (Harrier 18/80R)
| - Automatic rotor identification system
- The HARRIER range incorporates an automatic rotor identification system. This important feature ensures that the centrifuge recognises the rotor in use and prevents it from being used beyond its safe maximum speed. As the centrifuge identifies the rotor in use, it can also work out the ‘g’ force at any set speed. This means the centrifuge can convert rpm to ‘g’ and vice versa once in use.
- Microprocessor controlled induction drive
- The HARRIER range utilises an induction motor for maintenance free long life operation. This motor has no carbon brushes so not only is there no need for routine maintenance but there is no build-up of carbon dust inside the centrifuge. This makes it suitable for use in clean environments. Microprocessor control combined with the frequency driven motor ensures accurate operation for run to run reproducibility.
- Refrigerated version available
- The HARRIER 18/80 REFRIGERATED combines all the capabilities of the proven HARRIER 15/80 in a refrigerated format. The selectable temperature range is from −90C to +40C and uses CFC–free R134a refrigerant gas. This means that in refrigerant terms, the HARRIER 18/80 REFRIGERATED complies with all the regulations pertaining to the Montreal Protocol. A precool facility allows the bowl to be cooled to the required temperature prior to use.
- High speed microtube rotor
- The use of the induction motor provides another benefit in that higher rotational speeds can be achieved. This allows the HARRIER range to have a maximum speed in excess of 15,000 rpm with the 24 place microtube rotor. The addition of refrigeration in the HARRIER 18/80 REFRIGERATED unit allows the microtube rotor an increase in speed to 18,000 rpm giving a maximum ‘g’ force of 28,980 ‘g. See rotor table for details.
- Wide range of accessories available
- For routine bench top work, the 4 x 200ml swing out rotor and 200ml sealed buckets are available on the HARRIER 15/80. A recent addition on the HARRIER 18/80R is the 4 x 200ml windshielded rotor. This uses the same 200ml buckets as used on the HARRIER 15/80 but with an increased speed capability of 6,000 rpm giving a maximum g force of 6,466 g. These, combined with a wide range of adaptors, can accommodate most manufacturers’ tubes. As well as the swing out rotor, other angle rotors and specialist rotors are available. Please see tables for details.
Specifications
| Specifications |
| Max. Speed Swing–Out Rotor |
6,000 rpm |
| Max. RCF Swing–Out Rotor |
6,466 x g |
| Max. Speed Angle Rotor |
6,500 rpm |
| Max. RCF Angle Rotor |
5,574 x g |
| Max. Speed Microtube Rotor |
18,000 rpm |
| Max. RCF Microtube Rotor |
28,980 x g |
| Max. Bottle Size |
200ml |
| Max. Capacity |
800ml |
| Speed Control Range |
1–18,000 rpm |
| Speed Control Accuracy |
1 rpm |
| Speed Display |
±10 rpm |
| Temperature Range |
−9°C to +40°C |
| Temperature Control |
±2°C |
| Time Set Range |
| 0–59 mins 59 secs |
| 0–99 hours 59 mins |
| Time Hold | |
| Time Accuracy |
0.1 secs |
| Dimensions |
| Height |
355mm |
| Width |
470mm |
| Depth |
580mm |
| Weight |
41kg |
Adaptors
| Adaptors for 200ml Sealed Buckets (43551–1215) with 4 x 200ml Swing–Out Windshield Rotor (43124–141 – supplied with MSB080.CR2…) Max. Speed 4,500 rpm |
| Cat. No. |
Adaptor |
Colour |
Rotor Capacity |
Max. Dia. |
Min. Length |
Max. Length |
Max. g (4,500 rpm) |
Max. g (6,000 rpm) |
| 34159–3021 |
1 x 100ml |
Brown |
4 x 100ml |
39.5mm |
75mm |
118mm |
3,637 |
6,466 |
| 34159–3017 |
1 x 50ml |
Yellow |
4 x 50ml |
29.0mm |
72mm |
118mm |
3,637 |
6,466 |
| 34159–3040 |
7 x 15ml |
Green |
28 x 15ml |
17.0mm |
74mm |
118mm |
3,637 |
6,466 |
| 34159–3036 |
4 x 10ml (Flat Bottom Tube) |
Grey |
16 x 10ml |
16.5mm |
43mm |
110mm |
3,600 |
6,400 |
| 34159–3055 |
9 x 7ml |
Orange |
36 x 7ml |
13.0mm |
58mm |
118mm |
3,622 |
6,439 |
| 34159–306A |
12 x 5ml |
Blue |
48 x 5ml |
12.0mm |
49mm |
118mm |
3,637 |
6,466 |
| 34159–308 |
7 x 15ml (Flat Bottom Tube) |
Black |
28 x 15ml |
17.0mm |
74mm |
118mm |
3,577 |
6,359 |
| 34159–309 |
1 x 50ml Falcon |
Beige |
4 x 50ml |
29.0mm |
74mm |
120mm |
3,637 |
6,500 |
| 34159–310 |
3 x 15ml Falcon |
Maroon |
12 x 15ml |
17.0mm |
90mm |
120mm |
3,637 |
6,466 |
| Cat. No. |
Rotor Capacity |
Max. Dia. |
Min. Length |
Max. Length |
Max. g (4,500 rpm) |
Max. g (6,000 rpm) |
| 200ml Bottle (43551–103A) Does not require adaptor |
4 x 200ml |
57.7mm |
— |
120mm |
3,631 |
6,455 |
| Microtitration Rotor (43121–117) Max. Speed 2,600 rpm |
| Radius |
RCF |
Radius |
RCF |
No. Plates |
| 113mm |
854 |
130mm |
982 |
2 per Carrier (4 in total) |
| Angle Rotors |
| Rotor |
Capacity |
Bucket |
Adaptor |
Max. Speed |
Max. RCF |
| 43117–608 |
6 x 50ml |
43156–602 |
— |
6,500 rpm |
5,574g |
| 43117–607 |
12 x 15ml |
43156–601 |
— |
6,500 rpm |
5,290g |
| 43117–609 |
4 x 50ml (Sealed) |
43156–603 (Sealed Bucket) |
34142–110 50ml Falcon |
6,500 rpm |
4,812g |
| High Speed Angle Rotor. Optional Sealing Lid Available (43117–614) |
| Rotor |
Capacity |
Max. Speed |
Max. RCF |
| 43117–612 |
26 x 2ml |
18,000 rpm |
28,980g |
Ordering Information
| Model |
Description |
| MSB080.CR1.H |
Harrier 18/80 120V 60Hz |
| MSB080.CR1.K |
Harrier 18/80 220–230V 50Hz | Popular Systems
| Harrier 18/80 with 4 x 200ml Windshielded Swing–Out Rotor |
| Cat. No. |
Description |
Quantity |
| MSB080.CR… |
Order centrifuge to suit local voltage (see above) A 4 x 200ml Windshielded Swing–Out Rotor is supplied with the MSB080.CR2… but not with the MSB080.CR1… |
1 |
| 43551–1215 |
Sealed Buckets, Polycarbonate, 200ml (x4) |
1 |
| Adaptors |
Choose the relevant adaptors from above to suit your tubes (sold in sets of 4) |
1 |
| |
| Harrier 18/80 with 12 x 15ml Angle Rotor (unsealed) |
| Cat. No. |
Description |
Quantity |
| MSB080.CR… |
Order centrifuge to suit local voltage (see above) Order MSB080.CR1… if the 4 x 200ml Rotor supplied with MSB080.CR2… will never be used. |
1 |
| 43117–607 |
Angle Rotor, 12 x 15ml (x1) |
1 |
| 43156–601 |
Buckets, Stainless Steel, 15ml (x4) |
3 |
| |
| Harrier 18/80 with 6 x 50ml Angle Rotor (unsealed – not for use with Falcon tubes) |
| Cat. No. |
Description |
Quantity |
| MSB080.CR… |
Order centrifuge to suit local voltage (see above) Order MSB080.CR1… if the 4 x 200ml Rotor supplied with MSB080.CR2… will never be used. |
1 |
| 43117–608 |
Angle Rotor, 6 x 50ml (x1) |
1 |
| 43156–602 |
Buckets, 50ml (x4) |
2 |
| |
| Harrier 18/80 with 4 x 50ml Sealed Angle Rotor (can be used with Falcon tubes) |
| Cat. No. |
Description |
Quantity |
| MSB080.CR… |
Order centrifuge to suit local voltage (see above) Order MSB080.CR1… if the 4 x 200ml Rotor supplied with MSB080.CR2… will never be used. |
1 |
| 43117–609 |
Sealed Angle Rotor, 4 x 50ml |
1 |
| 43156–603 |
Sealed Bucket, Aluminium, 50ml (x4) |
1 |
| 34142–110 |
Adaptor, Conical, 50ml in 43156–603 (x12) |
1 |
| |
| Harrier 18/80 with 24 x 2ml Angle Rotor at 18,000 rpm |
| Cat. No. |
Description |
Quantity |
| MSB080.CR… |
Order centrifuge to suit local voltage (see above) Order MSB080.CR1… if the 4 x 200ml Rotor supplied with MSB080.CR2… will never be used. |
1 |
| 43117–612 |
Angle Rotor, 24 x 2ml at 15,000 rpm |
1 |
| Optional |
| 43117–614 |
Lid for 43117–612 (x1) |
1 |
| |
| Harrier 18/80 with Microtitration Rotor Plate |
| Cat. No. |
Description |
Quantity |
| MSB080.CR… |
Order centrifuge to suit local voltage (see above) Order MSB080.CR1… if the 4 x 200ml Rotor supplied with MSB080.CR2… will never be used. |
1 |
| 43121–117 |
Microtitre Rotor |
1 |
|